MARLOTHERM Product Comparison
| MARLOTHERM | X | FP | LH | N | SH |
|---|---|---|---|---|---|
| Temperature range, bulk outlet Liquid phase: Non-pressurized, °F Pressurized Vapor phase |
-112 to 356 Yes to 572 Yes |
140 to 572 N/A No |
-22 to 536 Yes to 680 Yes |
140 to 572 N/A No |
140 to 662 N/A No |
| Pumping limits, °F | <-112 | 14 | -22 | 14 | 23 |
| Pour Points, °F | <-130 | 10 | -22 | -76 | -30 |
| Normal Boiling Points, °F | 356 | 644 to 887 | 532 to 540 | 626 to 752 | 725 to 743 |
| Flash Points, ASTM D-92, °F ASTM D-93, °F |
147 133 |
432 417 |
288 266 |
385 356 |
421 392 |
| Autoignition temperature, °F | 770 | 617 | 842 | 626 | 842 |
| Molecular weight | 134 | - | 182 | 330 | 272 |
| Composition Appearance @ 68 °F Odor |
Aromatic Clear liquid Distinct |
Aliphatic Clear Liquid Bland |
Aromatic Clear liquid Mild |
Aromatic Clear liquid Distinct |
Aliphatic Clear liquid Bland |
| Vapor pressure, psi 0 °F 100 °F 300 °F 572 °F |
- 0.05 6.00 158.1 |
- - 1.89 8.10 |
- - 0.30 23.5 |
- - - 3.4 |
- - - 2.9 |
| Viscosity, cSt -40 °F 0 °F 100 °F 300 °F 572 °F |
3.50 1.94 0.88 0.34 0.24 |
- 156 22.8 2.00 0.52 |
- 14.5 2.65 0.64 0.30 |
- 719 28 1.6 0.38 |
- 1091 21 1.09 0.45 |
| Density, lb/ft3 0 °F 100 °F 300 °F 572 °F |
56.0 53.2 47.2 39.5 |
53.8 52.2 47.8 41.4 |
63.9 61.3 56.1 47.8 |
56.3 54.1 49.3 41.8 |
66.8 64.4 59.4 52.7 |
| Thermal conductivity, Btu/ft-hr-°F 0 °F 100 °F 300 °F 572 °F |
0.081 0.073 0.057 0.034 |
0.078 0.076 0.072 0.067 |
0.079 0.075 0.067 0.057 |
0.079 0.077 0.072 0.060 |
0.078 0.074 0.066 0.054 |
| Specific heat, Btu/lb-°F 0 °F 100 °F 300 °F 572 °F |
0.416 0.432 0.521 0.683 |
0.453 0.478 0.563 0.718 |
0.353 0.400 0.489 0.609 |
0.434 0.482 0.583 0.714 |
0.337 0.386 0.484 0.610 |
N/A - Not applicable in recommended usage range.
All data for liquid phase. No data given outside of recommended use range.